摘要:

采用低强度超声强化Oxone/Co2+氧化工艺(US/Oxone/Co2+)处理COD为1116 mg/L、SS为17mg/L、色度为300倍、TOC为29.04mg/L、pH值为8.17的垃圾渗滤液,以COD的去除率为主要指标,探讨了pH、反应温度、[Oxone]/[Co2+]、试剂投加量、超声强度、反应时间、试剂投加方式对处理效果的影响.结果表明:在超声功率为50 W、频率为40kHz、强度为60%,[Oxone]为3mmol/L、[Oxone]/[Co2+]为500 000、pH为9.0、反应初始温度为25℃、反应时间35min、Oxone投加次数为6的最佳条件下,垃圾渗滤液的COD,TOC,SS和色度去除率分别达到63.74%、59.46%、69.35%和83.33%.

The treatment of landfill leachate(COD=1116mg/L,SS=17mg/L and chrominance=300)by low-intensity ultrasonic assisted US/Oxone/Co2+was carried out,the effects of operating conditions such as pH value,reaction temperature,[Oxone]/[Co2+],Oxone's reagent dosage,ultrasonic sound intensity,reaction time and dosing mode on COD removal were investigated.The results indicated that under the optimal operational conditions such as:ultrasonic power=50 W,ultrasonic frequency=40kHz,ultrasonic intensity=60%,[Oxone]=3mmol/L,[Oxone]/[Co2+]=5×105,pH=9.0,original reaction temperature=25 ℃,reaction time=35 min,number of stepwise addition=6,the removal of COD,TOC,SS and chrominance achieved 63.74%,59.46%,69.35% and 83.33%,respectively.

作者:

李晓艳 苏现伐 皮运清 孙剑辉

机构地区:

betway官方app 环境学院 黄淮水环境与污染防治教育部重点实验室 河南省环境污染控制重点实验室 河南省焦作市环境监测站

出处:

《betway官方app 学报:自然科学版》 CAS 北大核心 2017年第5期28-33,共6页

基金:

国家自然科学基金(21477034)

关键词:

高级氧化技术 US/Oxone/Co2+ 垃圾渗滤液

Advanced Oxidation Technologies(AOTs) US/Oxone/Co2+ landfill leachate

分类号:

X703.1 [环境科学与工程—环境工程]